LIMITING SYNCHRO LOADS IN 400 CYCLE CONTROL, TORQUE AND MIXED SYSTEMS FOR MIL-S-20708A SYNCHROS.

Abstract

Limiting synchro loads in 400 cycle systems, load current for 3 percent voltage regulation and optimum capacities have been determined for synchros fabricated under military specification MIL-S-20708A. Limiting loads have been determined from measured synchro parameters, applied to formulae developed by the Laboratory. Synchro loads that may be carried in control, torque and mixed control-torque systems are tabulated in the report. Load currents and optimum values for synchro capacitors, two of the parameters used to determine synchro loads, are also tabulated. (Author)

Document Details

Document Type
Technical Report
Publication Date
Jan 01, 1964
Accession Number
AD0607175

Entities

People

  • J. Locker

Tags

DTIC Thesaurus Topics

  • Buildings And Structures
  • Capacitors
  • Electronic Components
  • Electronic Equipment
  • Law
  • Regulations
  • Specifications
  • Voltage Regulation

Readers

  • Electrical Engineering