PRODUCTION ENGINEERING MEASURE. MICROELEMENT DIODES.
Abstract
Considerable difficulty was experienced when diodes were soldered onto the microelement lands. The difficulty was particularly pronounced under 200C storage. Under this condition, tin-lead and tin-lead-silver solders oxidized and the joint increased in resistance to an unacceptable degree, or opened completely. Superior results were achieved by the use of axial-leaded diodes (round or flat leads) mounted on the wafer, as compared to a 'button' style set into the wafer. The performance of the diodes themselves was generally very good. Evidence was obtained which indicated that the diodes were not damaged unduly by the mounting procedure, but that they benefitted from a 200C, 1000 hour burn-in prior to mounting. No appreciable difference was observed between alloy and diffused junction diodes. Some difficulty was experienced with the microelement wafers. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Nov 01, 1964
- Accession Number
- AD0608775
Entities
Organizations
- RTX