Preproduction testing of 1800 samples of two styles of the subminiature potentiometers resulted in failures only on Visual and Mechanical inspection, rotational life, and moisture resistance. 1600 samples of both styles are being rebuilt for retesting to demonstrate compliance with the technical requirements of the contract. A revised time schedule has been resubmitted for the completion of the contract. 2400 units continue on the 10,000 hour load life reliability study and have completed 7,000 hours for a total of 16,800,000 unit hours. (Author)