PRODUCTION ENGINEERING OF TRIAXIAL PULSE CONNECTORS.

Abstract

Engineering Samples of the UG1292()/U and UG1291()/U Connector assemblies were tested and evaluated. Certain modifications to the design are necessary to assure proper termination of the first shield, to assure proper elimination of air voids at the mating surfaces. Engineering Samples of the UG1296()/U, P-230 and P-190 connector assemblies were tested and evaluated. Corona characteristics after temperature cycling indicated a degree of degradation of the cable has taken place. This was quite apparent relative to the RG230/U cable. (Author)

Document Details

Document Type
Technical Report
Publication Date
Sep 30, 1964
Accession Number
AD0609395

Entities

People

  • Maxwell E. Peel

Tags

DTIC Thesaurus Topics

  • Assembly
  • Connectors
  • Degradation
  • Elimination
  • Engineering
  • Manufacturing
  • Mass Production
  • Production
  • Production Engineering
  • Production Management Methods

Readers

  • Electrical Engineering
  • Geotechnical Engineering.