PRODUCTION ENGINEERING OF TRIAXIAL PULSE CONNECTORS.
Abstract
Engineering Samples of the UG1292()/U and UG1291()/U Connector assemblies were tested and evaluated. Certain modifications to the design are necessary to assure proper termination of the first shield, to assure proper elimination of air voids at the mating surfaces. Engineering Samples of the UG1296()/U, P-230 and P-190 connector assemblies were tested and evaluated. Corona characteristics after temperature cycling indicated a degree of degradation of the cable has taken place. This was quite apparent relative to the RG230/U cable. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Sep 30, 1964
- Accession Number
- AD0609395
Entities
People
- Maxwell E. Peel