STATE MODELS OF ACTIVE RLC NETWORKS,

Abstract

In active RLC networks in which dependent sources are controlled by passive elements, the existence of a tree which contains all voltage sources as branches and all current sources as chords is only a necessary condition for a unique solution. Unlike the passive case, the order of state vector depends not only on the topology of the network but also on the controlling coefficients of the dependent sources in the network. Furthermore, in passive case if state variables are the currents of inductors and voltages of capacitors, at most the first derivative of the input vector u may appear in the state model but in active case the nth derivative may appear, where n is the number of reactive elements in the network.

Document Details

Document Type
Technical Report
Publication Date
Dec 01, 1964
Accession Number
AD0609700

Entities

People

  • Ahmet Dervisoglu

Organizations

  • University of Illinois Urbana–Champaign

Tags

DTIC Thesaurus Topics

  • Air Force
  • Capacitors
  • Coefficients
  • Electronic Components
  • Electronic Equipment
  • Inductors
  • Military Research
  • Passive Electronic Components
  • Scientific Research
  • Topology

Readers

  • Graph Algorithms and Convex Optimization.
  • Microwave Engineering.
  • Plasma Physics.