DUPLEXER FOR SIDE-LOOKING RADAR.
Abstract
A three-cavity limiter was designed and constructed in which the middle resonator is a single crystal YIG sphere. High power tests have shown limiting to occur at 50 watts peak, and continuing to a level of 30 KW. A total of fifteen materials were evaluated in the three-port circulator. Peak power measurements were made to a level of 500 KW, one composition exhibits .45 db loss at this level. The phase shift section of the four-port circulator was tested at 200 KW peak power. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Dec 30, 1964
- Accession Number
- AD0617568
Entities
People
- Donald A. Lepore
- E. Wantuch
- J. W. Nielsen
- Morrell L. King