PRODUCTION ENGINEERING MEASURE CR-(XM-53)/U QUARTZ CRYSTAL UNITS.

Abstract

Accurate measurements of effective resistance were attained at the 2-microwatt drive level by making minor modifications to the TS-330(AGC) test set to permit it to function as a 'Transmission line' circuit. These more accurate measurements disclosed that there were problems in meeting the 1,000,000 Q at the 5-Mc level as well as at the 1-Mc level, where several mounting arrangements had been evaluated without success. The various mounting arrangements are described, as well as the current approaches which involve attainment of higher Q levels by the quartz resonators themselves, rather than complete dependence on the mounting arrangements. (Author)

Document Details

Document Type
Technical Report
Publication Date
Apr 01, 1965
Accession Number
AD0618490

Entities

People

  • J. M. Wolfskill
  • Merle George
  • Robert Mouck

Tags

DTIC Thesaurus Topics

  • Engineering
  • Measurement
  • Production
  • Production Engineering
  • Production Management Methods
  • Productivity
  • Quartz Resonators
  • Resonators
  • Test Sets
  • Transmission Lines

Readers

  • Electronics Engineering
  • Regression Analysis.