MEASUREMENT OF STRESS ON MARTIN-BAKER EJECTION SEAT FACE CURTAIN.

Abstract

A study was conducted to determine the amount of static pull that could be exerted in situ on the face curtain of the Martin-Baker Ejection Seat. To measure the pull, a hydraulic pressure measuring device was fabricated and attached to the curtain handles. A selected population of 252 subjects completed three maximum pulls each on the curtain. Mean age, weight, and height was 23.5 years, 163.7 pounds and 5 feet 9-3/4 inches respectively. The mean average pull of all subjects was 57.3 pounds with a standard deviation of 14.4 pounds. The absolute range for single trials was 17 to 107 pounds. It is recommended that further studies of dynamic pull on the curtain in situ, maximum pull under ideal conditions, and the effect of positive 'g' on pull be made. (Author)

Document Details

Document Type
Technical Report
Publication Date
Oct 23, 1950
Accession Number
AD0620277

Entities

People

  • Arthur L. Hall
  • Lynn A. Alford

Organizations

  • Naval Aerospace Medical Institute

Tags

DTIC Thesaurus Topics

  • Data Science
  • Ejection
  • Ejection Seats
  • Hydraulic Pressure
  • Information Science
  • Measurement
  • Pressure Measurement
  • Seats
  • Standards

Readers

  • Electrical Engineering
  • Materials Science
  • Regression Analysis.