STUDY AND INVESTIGATION OF A PORTED COLOR CATHODE RAY TUBE.

Abstract

A combined analytical and experimental study has been conducted to determine the feasibility of building a 23-inch rear-ported full color monitor employing the 'Goodman' x-ray beam indexing principle. The study has resulted in the development of a large experimental tube incorporating a 2 inch beryllium window, which in conjunction with a scintillator/pmt detector has provided high-speed x-ray index pulses. Circuits have been devised to process the index signal to time color video pulses to the crt grid. Simultaneous rear projection has also been demonstrated in the experimental tube. A 1000 color line tube and circuit capability is projected. (Author)

Document Details

Document Type
Technical Report
Publication Date
Sep 01, 1965
Accession Number