PRODUCTION ENGINEERING OF TRIAXIAL PULSE CONNECTORS.
Abstract
Five engineering samples (plugs and receptacles) for RG-156/U Cable were manufactured per SKM15357. Qualification testing of these 5 units was begun. A mechanical aid, in the form of a positive, bi-directional mechanical stop should be incroporated in the design of the receptacle insert holding area. This would prevent loosening of the insert when the connectors are inadvertently mated with excessive force.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jun 30, 1965
- Accession Number
- AD0623176
Entities
People
- Mark L. Auriana