FACTORS AFFECTING TRANSISTOR FAILURE IN DC TO DC CONVERTERS.
Abstract
The purpose of this report is to indicate assignable causes of failure of transistors in dc to dc converters. While seemingly power transistor converter failures occur with no apparent cause after many cycles of operation, an examination of the load characteristics can reveal a potential failure pattern. The load line characteristic coupled with the safe area limits of the transistor has revealed potential failure patterns in converters described in this report. This analysis has lead to a much better understanding of transistor failures observed with the types of converters analyzed. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Jul 01, 1965
- Accession Number
- AD0623359
Entities
People
- Bernard Reich
Organizations
- United States Army Communications-Electronics Command