PRODUCTION ENGINEERING MEASURE FOR IMPROVED RELIABILITY OF SOLID ELECTROLYTE TANTALUM CAPACITORS.
Abstract
Failure analysis of the third pilot run units revealed an unexpected failure mode. Cause for failure appeared to be contamination of the anodes by the riser stop-off material. The production run capacitors were examined and thirteen lots were rejected. An improved Process Inspection Point procedure was instituted before production scheduling replacement lots. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Jun 29, 1965
- Accession Number
- AD0624748
Entities
People
- A. W. H. Smith