HIGH POWER FERRITE GAS DUPLEXER.

Abstract

Analysis of the test results on the second YIG-D prototype duplexer indicate that the failure is due neither to non-linear behavior with peak power nor defective epoxy bonding, but to limitations in the thermal transfer properties of the YIG-D material. Further effort to reduce the length of the final duplexer design using YIG-D material are fruitless and should concentrate on optimizing the design of the previously successful TT2-113 model. (Author)