CURRENT-RATING TABLES FOR BUNDLED AIRCRAFT CABLES CARRYING CONTINUOUS D-C CURRENTS

Abstract

A tabular method for rating bundled cables carrying continuous d-c currents was devised. The tabular method can be applied to any given set of cables, e.g., MIL-W-5086, MIL-W-7072, etc., for a wide range of bundle installation and environmental conditions. The method of computing and compiling the necessary data is explained. An example of one pair of cable- rating and -selection tables is given along with illustrations which show their use in finding the correct cable sizes when the currents are given and in finding the currents when the bundled cables are given. The tables are applied to a number of bundles and the results compared with MIL-W-5088A ratings. The results show that the latter may seriously underload or overload cables in bundles. Application of the proposed rating methods will lead to the lowest cable weight consistent with the safety of the aircraft. It is recommended that the tabular method be applied to several aircraft to gain needed information and experience before incorporation of the tables into the cable-rating specification is effected.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Mar 01, 1955
Accession Number
AD0625901

Entities

People

  • Milton Schach

Organizations

  • United States Naval Research Laboratory

Tags

Communities of Interest

  • Air Platforms

DTIC Thesaurus Topics

  • Air Force
  • Aircrafts
  • Conductivity
  • Dissipation
  • Electronics
  • Emissivity
  • Equations
  • Heat Transfer
  • Insulation
  • Intervals
  • Measurement
  • Military Research
  • Overload
  • Resistance
  • Specifications
  • Thermal Conductivity
  • United States

Readers

  • Electrical Engineering
  • Optical Fiber Sensing and Electromagnetic Propagation.
  • Systems Analysis and Design