PRODUCTION ENGINEERING MEASURE FOR TYPE CR-(XM-60)/U CRYSTAL UNITS.
Abstract
The new Kold-Weld holders were utilized in a 20 unit crystal group now under test. Evaluations will be made at the end of the test. Thermo-compression bonding had been abandoned early in the program in favor of ultrasonic welding. Efforts, however, will be resumed if ultrasonic welding does not prove practical. The re-evaluation of the reliability data uncovered some serious questions concerning the drive levels of the units under test. The CR-(XM-60)/U units to be manufactured are expected to have much lower resistance values than the present CR-47A/U units, because of process improvements including primarily, the evacuation of the Kold-Weld holders. Under these conditions, the drive levels may very well be in excess of five times the specification, a factor contributing to an increased aging rate, and perhaps, a poorer reliability rate than that of the CR-47A/U units. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Dec 01, 1965
- Accession Number
- AD0633688
Entities
People
- G. A. Lagasse