THERMOCHEMICAL TESTS OF DOMESTIC TURBINE DRIVEN SHIPS,
Abstract
The standards for the quality of feed water and boiler water, which have been accepted by the instructions for servicing of KVG-25 and KVG-34 boilers, which are installed on the LENINSKIY KOMSOMOL and PEKIN class of ships should be changed; these standards should take into consideration the operation of these ships by the Black Sea Agency and the conducted thermal-chemical tests. As a result, the salinity of the feed water should be decreased from 6 to 1 mg/kg Cl' and the boiler water from 0-275 to 0-50 mg/kg, and at most, up to 0-180 mg/kg Cl'; the alkaline number of boiler water should be decreased from 11-100 to 10-50 mg/kg NaOH. Under normal operating conditiions, the drainage of the boiler should constitute 0.2-0.5% instead of the previously established 2%. The salt content in the saturated steam should not exceed 0.1 mg/kg.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jan 01, 1966
- Accession Number
- AD0633926
Entities
People
- A. Goldenfon
- R. Taranenko
Organizations
- United States Department of the Navy