MECHANICAL SHOCK RESISTANCE OF THREADED FASTENERS
Abstract
An investigation was made of the mechanical shock resistance of K- Monel full-body studs set in HY-80 steel under various conditions. Strain gages mounted on the stud shanks were used to measure dynamic loading. Elastic nylon- insert monel stop nuts were used throughout the test. The data indicated that for the conditions of the test Locktite-coated 3A-3B threads are equal in shock resistance to uncoated 5A-5B threads, and that the elastic stop nuts are reusable after repeated shock.
Document Details
- Document Type
- Technical Report
- Publication Date
- Oct 01, 1966
- Accession Number
- AD0639953
Entities
People
- John R. Braden
- Richard E. Heise Jr.