ESTABLISHMENT OF STANDARDIZATION DATA FOR MONEL AND K-MONEL FASTENERS.

Abstract

The purpose of testing performed in this task is (1) to determine thread distortion caused by various amounts of thread interference, (2) to evaluate changes in material as a result of thread interference, length of engagement, and axial stud loading to its breaking point, and (3) to produce comparative data on break-away torque and prevailing back-out torque of the stud, and corresponding torques for backing off self locking nuts.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Apr 06, 1965
Accession Number
AD0643663

Entities

People

  • E. Goodman
  • Jennifer A. Miller
  • T. Hogland

Tags

Communities of Interest

  • Ground and Sea Platforms

DTIC Thesaurus Topics

  • Axial Loads
  • Diameters
  • Distortion
  • Elongation
  • Engineering
  • Fasteners
  • Handbooks
  • Materials
  • Plastic Flow
  • Shoulder
  • Stress Tests
  • Stresses
  • Test Equipment
  • Test Sets
  • Thickness
  • Value Engineering

Fields of Study

  • Physics

Readers

  • Electrical Engineering
  • Metallurgy
  • Systems Analysis and Design