INVESTIGATION OF THE BOILING OF LIQUIDS IN VERTICAL TUBES.

Abstract

The project investigated experimentally the boiling of water in vertical tubes up to pressures of 1450 lbs/sq. in. Basically the apparatus for evaporating the water consisted of a stainless steel tube, two meters in length having an inside diameter of 16mm, and an outside diameter of 20mm. This was heated by a transformer attached to the tube and energized by 50 cycle alternating current. Experiments were made with heat fluxes up to 7.8 Watts/sq. cm at temperatures from 114 to 165C. (Author)

Document Details

Document Type
Technical Report
Publication Date
Oct 01, 1966
Accession Number
AD0644359

Entities

People

  • Ernst Schmidt

Tags

DTIC Thesaurus Topics

  • Alternating Current
  • Diameters
  • Heat Flux
  • Stainless Steel
  • Steel
  • Transformers

Fields of Study

  • Engineering
  • Physics

Readers

  • Combustion and Flow Dynamics.
  • Electronics Engineering
  • Plasma Physics.