TEST PROCEDURES FOR FORCED AIR COOLED EQUIPMENT.
Abstract
A test procedure for temperature-altitude testing of forced air cooled equipment using conventional recirculating chambers is proposed. Test results showing performances of forced air cooled TACAN AN/ARN-52(V) at various temperature-altitude conditions with and without cooling air is presented and discussed in relation to existing specifications MIL-E-5400 and MIL-T-5422. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Jan 10, 1967
- Accession Number
- AD0647150
Entities
People
- B. Plizak
Organizations
- Naval Air Warfare Center Warminster