EVALUATE TACAN SEPARATE SQUITTER SOURCE.

Abstract

A modification for the R-865 and R-865A/GRN-9C receivers was tested. The modification was designed to eliminate DME false replies at certain TACAN enroute navigation aid facilities. It was concluded that the modification would eliminate the DME false reply problem but at a cost of decreased receiver sensitivity of about 2 to 3 dBm for the units tested. (Author)

Document Details

Document Type
Technical Report
Publication Date
Dec 01, 1966
Accession Number
AD0651221

Entities

People

  • Donald L. Fehr

Tags

DTIC Thesaurus Topics

  • Navigation
  • Sensitivity

Readers

  • Aviation Safety and Air Traffic Management
  • Radar Systems Engineering.