WIDE-ANGLE INTERNAL DEFLECTION STRUCTURES OF CATHODE-RAY TUBES.

Abstract

Theoretical studies were made to derive suitable forms of the focal length of a deflection system and with the effect of isolation electrodes between the horizontal and vertical deflection systems. Discussion led to the design of an electron gun, suitable for studies of dynamic correction of deflection defocussing by means of electrodes in the main lens which have elliptical apertures. This gun will be ready for tests early in December 1966. Studies continue to determine theoretically the functional relation between deflection voltage and dynamic correction voltage. (Author)

Document Details

Document Type
Technical Report
Publication Date
Apr 01, 1967
Accession Number
AD0652718

Entities

People

  • Rudolf G. E. Hutter

Organizations

  • New York University Tandon School of Engineering

Tags

DTIC Thesaurus Topics

  • Cathode Ray Tubes
  • Deflection
  • Electrodes
  • Electron Guns
  • Electron Tubes
  • Electronic Equipment
  • Electrons
  • Wide Angles

Fields of Study

  • Physics

Readers

  • Electronics Engineering
  • Seismology

Technology Areas

  • Microelectronics
  • Microelectronics - Microelectromechanical Systems