A REPETITIVE MECHANICAL PHOTOFLASH TIMER FOR THE MILLISECOND REGION,
Abstract
A mechanical timer has been developed which has a useful range from 0.10 to 100 milliseconds with an error of plus or minus 15.0 microseconds. It has been used successfully in connection with high-speed, multiple exposure photography in applications where electronic timers could not be employed. The device is constructed from standard, easily obtained parts. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Dec 20, 1957
- Accession Number
- AD0655421
Entities
People
- Spencer Raezer
Organizations
- Johns Hopkins University Applied Physics Laboratory