TEMPERATURE MEASUREMENTS IN EXPERIMENTAL TUMORS FOLLOWING EXPOSURE TO RUBY LASER ENERGY.

Abstract

An approach to accurate measurement of time temperatures with an implanted thermocouple following ruby laser exposure is described. The problems inherent in such measurements are discussed. This method indicates a linear reciprocal correlation between temperature and depth from 0.25C/joule at 2 mm depth to 0.11C/joule at 5 mm depth. (Author)