WIDE-ANGLE INTERNAL DEFLECTION STRUCTURES OF CATHODE-RAY TUBES.
Abstract
Factors that determine spot size in cathode-ray tubes are examined. The suitability of a 'modified Pierce gun' for use in cathode-ray tubes is being investigated. A method for measuring spot size and current distribution in the spot is analyzed. Electron guns for use in a multigun cathode-ray tube were designed. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Feb 01, 1968
- Accession Number
- AD0666794
Entities
People
- Rudolf G. E. Hutter
Organizations
- New York University Tandon School of Engineering