EDISON BY BATTERIES IN BUOYS.
Abstract
Controlled and monitored service tests of Edison BY batteries, an air-depolarized primary cell with liquid electrolyte that was specifically designed for use on aids to navigation buoys, began in 1964. This final report presents the results of the tests concerning capacity, the effects of age on capacity, and the effect of air starvation on capacity. Additionally, recommendations are made stressing procedures that should facilitate accurate calculation of capacity in future in-service battery evaluations. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Jan 01, 1968
- Accession Number
- AD0667579
Entities
People
- J. T. Montonye