RESPONSE OF A SINGLE DEGREE OF FREEDOM SYSTEM TO VARIOUS TRANSIENTS

Abstract

The ratio of maximum deflection of a one degree of freedom system to the static deflection (corresponding to the peak force) is approximately independent of pulse shape (within plus or minus 5%) for effective pulse durations (impulse/peak force) less than about 20% of the free natural period of the system. The above deflection ratio equals unity when the effective pulse duration is about 17 to 18% of the free natural period of the system for an undamped system. For damped systems the duration for unity deflection ratio is somewhat greater.