MERCURY ARC PLASMA TUBE DIAGNOSTIC STUDY. PART II. MICROWAVE PROBE STUDY,
Abstract
This report presents the results of a microwave diagnostic study performed on a mercury arc plasma tube. Utilizing a microwave reflection technique, the electron density in the tube was calibrated as a function of the arc current. Comparison of the results with Langmuir probe measurements previously reported shows good agreement. An outline of the theory pertaining to this study is also included. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Aug 01, 1968
- Accession Number
- AD0676823
Entities
People
- John A. Rosado
- William L. Vault
Organizations
- Harry Diamond Laboratories