THE TEMPERATURE SENSITIVITY OF A COMMERCIAL METAL FILM RESISTOR.
Abstract
The temperature coefficient of a commercial metal film resistor has been investigated over a temperature range of 25C to 50C. It has been found to have a magnitude of less than plus or minus 1.5 ppm/C deg which upholds the manufacturer's claim. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Jul 01, 1968
- Accession Number
- AD0683078
Entities
People
- J. A. Andrew
Organizations
- Royal Aircraft Establishment