RELIABILITY OF MILITARY CRYSTAL UNITS UNDER CLIMATIC ENVIRONMENTAL CONDITIONS.

Abstract

The report presents the results of a 4-1/4-year investigation on military quartz crystal units in the HC-6/U enclosure which have been stored under moderate climatic environmental conditions. Crystal units being reported upon operated on their fundamental, third and fifth overtone modes and covered the frequency range of 4.3 to 100.0 MHz. Data on crystal aging and changes in resistance are discussed. Apparent manufacturing defects which result in crystal unit failures are explained. (Author)

Document Details

Document Type
Technical Report
Publication Date
Nov 01, 1968
Accession Number
AD0683460

Entities

People

  • Lewis Nelson

Organizations

  • United States Army Communications-Electronics Command

Tags

DTIC Thesaurus Topics

  • Frequency
  • Manufacturing
  • Reliability

Readers

  • Aerospace Test and Evaluation
  • Materials Science and Engineering.
  • Microwave Engineering.