THE DESIGN AND OPERATION OF A HIGH MACH NUMBER-REYNOLDS NUMBER FACILITY.

Abstract

A facility capable of operating at Mach number 10, and a Reynolds number of 2x10 to the 7th power/ft was designed, built and calibrated. The facility is capable of operating at stagnation pressures up to 30,000 p.s.i., and a stagnation temperature of 1800R. A running time of three seconds is available with the present design; however, an increase in the running time may be obtained by increasing the air storage system. A method for increasing the stagnation temperature capability of the facility to 3500R is also outlined within the main body of the report. (Author)

Document Details

Document Type
Technical Report
Publication Date
Dec 01, 1968
Accession Number