OPERATING CHARACTERISTICS OF A MULTI-MEGAWATT ARC HEATER USED WITH THE AIR FORCE FLIGHT DYNAMICS LABORATORY 50-MEGAWATT FACILITY.

Abstract

The operational capabilities of a 50-megawatt arc heater facility are discussed. The operating characteristics of the heater with throat diameters of one inch and two inches are reported. Design modifications made to the heater during the course of this investigation extended the usable power limit to approximately 35 megawatts at a stagnation pressure in excess of 100 atmospheres. Representative flow surveys are presented of the pitot pressure and stagnation point heat transfer rate which were obtained at the exit of a two-foot diameter nozzle. (Author)

Document Details

Document Type
Technical Report
Publication Date
Apr 01, 1969
Accession Number
AD0687880

Entities

People

  • James L. Folck
  • Richard T. Smith

Organizations

  • Flight Dynamics Laboratory

Tags

DTIC Thesaurus Topics

  • Air Force
  • Arc Heaters
  • Atmospheres
  • Buildings And Structures
  • Diameters
  • Dynamics
  • Heat Transfer
  • Heaters
  • Physics Laboratories
  • Research Facilities
  • Stagnation Point
  • Stagnation Pressure

Fields of Study

  • Physics

Readers

  • Fluid Dynamics.