A DESIGN OF A CONSTANT TEMPERATURE CHAMBER.
Abstract
A requirement for an effective constant ambient temperature chamber for a precision oscillator clock led to the development of the apparatus described in this report. A temperature variation smoothing ratio of 30 to 1 with a 5 hour lag was readily achieved with this inexpensive and simple apparatus. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Aug 01, 1969
- Accession Number
- AD0694456
Entities
People
- Alan W. Baldwin
Organizations
- United States Naval Research Laboratory