IMPEDANCE PER UNIT LENGTH BETWEEN TWO LONG HORIZONTAL WIRES ABOVE THE EARTH'S SURFACE,
Abstract
The external impedance per unit length of a long, elevated, horizontal line source and the mutual impedance per unit length between two parallel, elevated line sources are derived for the quasi-static range by employing image theory. The image theory and previously derived analytical results are in very good agreement throughout the quasi-static range. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Aug 13, 1969
- Accession Number
- AD0697279
Entities
People
- Peter R. Bannister
Organizations
- Navy Underwater Sound Laboratory