RESEARCH ON OCULAR LASER THRESHOLDS
Abstract
Results of experimental investigations of threshold levels for small retinal lesions are presented. Data for rhesus monkeys include thresholds for a Q-switched neodymium laser, both in the macula and in the paramacular area. In addition, extensive data are presented for argon, helium-neon, and neodymium-YAG laser damage threshold. Exposures of human volunteers to various lasers are reported. The lasers used were Q-switched neodymium and ruby lasers, a long- pulse ruby laser, and an argon laser. A report on the histopathology of retinal injury in rhesus monkeys due to Q-switched neodymium and argon lasers is included.
Document Details
- Document Type
- Technical Report
- Publication Date
- Aug 01, 1969
- Accession Number
- AD0700422
Entities
People
- Arthur Vassiliadis
- H. Cristian Zweng
- Robert C. Rosan
Organizations
- SRI International