CALIBRATION OF THE NOL LARGE SCALE GAP TEST WITH A PENTOLITE DONOR II
Abstract
Henceforth the standard donor in the NOL large scale gap test will be 50/50 pentolite pellets pressed to a density of 1.56 g/cc instead of the tetryl pellets previously used. The pentolite donors will be supplied by NAD, Crane, Indiana. This report gives the current calibration curve for the large scale gap test with the pentolite donors.
Document Details
- Document Type
- Technical Report
- Publication Date
- Mar 17, 1970
- Accession Number
- AD0706705
Entities
People
- Donna Price
Organizations
- Naval Ordnance Laboratory