MEASUREMENT OF THE DIELECTRIC CONSTANT OF TRIGLYCINE SULFATE AT MICROWAVE FREQUENCIES.
Abstract
Described is the construction and operation of a microwave system used to measure very high dielectric constants over wide frequency and temperature ranges. Measurements of the dielectric constant of the ferroelectric triglycine sulfate are reported over a frequency range of 4.0 to 12.0 GHz. The results agree fairly well with those reported by other investigators. Sources of errors and possible improvements in this experiment are discussed. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Jun 01, 1970
- Accession Number
- AD0709930
Entities
People
- Raymond L. Anderson
Organizations
- Naval Postgraduate School