An Investigation of Fracture by the Use of Microstrain Gauges.
Abstract
Experimental techniques for the fabrication of a piezoelectric strain gauge device are described. ZnS films vapor deposited on a tensile specimen are capable of giving strain measurements of .0000001 inches/inches and have a time resolution of .00000001 sec. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Jan 31, 1971
- Accession Number
- AD0717649
Entities
People
- J. Bevil