Determination of Proof Test Level for Test-Degradable Components.

Abstract

Conventional proof testing practice yields a component population with an initial reliability of 1.0, when viewed from the standpoint of stress/strength interference theory. The proof test is reviewed for the case of test-degradable components. Methodology is developed which allows the determination of an optimum test level. This theory is applied to filament-wound pressure vessels, and it is found that test- degradable components require a proof test usage entirely different from that followed with components not subject to this degradation. (Author, modified-PL)

Document Details

Document Type
Technical Report
Publication Date
Nov 20, 1970
Accession Number
AD0720576

Entities

People

  • A. R. Maykut

Organizations

  • United States Army Aviation and Missile Command

Tags

DTIC Thesaurus Topics

  • Degradation
  • Filaments
  • Pressure Vessels

Readers

  • Structural Health Monitoring of Composite Structures.
  • Theoretical Analysis.