Acoustic Flowmeter Prototype Evaluation Tests.

Abstract

Prototype tests of an acoustic flowmeter system were made in a 24-ft-diam power penstock at Oahe Dam to evaluate the system prior to permanent installation in the outlet works at Summersville Dam. Comparative discharge measurements included acoustic, penstock pressure-momentum (Gibson), turbine model test ratings, scroll-case pressure differential (Winter-Kennedy flowmeter), and surge tank volume changes. The acoustic flowmeter measurements were very consistent and many of the comparisons were within 1%. The location of the measuring section for a single-path acoustic flowmeter must be selected to give a known or measurable relation between the flow pattern of the whole section and that along the acoustic path. (Author)

Document Details

Document Type
Technical Report
Publication Date
Jan 01, 1968
Accession Number
AD0723983

Entities

People

  • Ellis B. Pickett

Tags

DTIC Thesaurus Topics

  • Determinants (Mathematics)
  • Flowmeters
  • Measurement
  • Measuring Instruments
  • Model Tests
  • Models
  • Momentum
  • Pressure Measurement
  • Prototypes
  • Test And Evaluation

Fields of Study

  • Physics

Readers

  • Aerospace Test and Evaluation
  • Electromagnetic Wave Scattering and Antenna Radiation Engineering
  • Hydrologic Risk Analysis and Mitigation.