Operating Forces on Sector Gates under Reverse Heads. Appendix A. Results of Supplemental Tests. Hydraulic Model Investigation.

Abstract

Subsequent to the model tests discussed in the basic report, certain revisions were made to the improved sector gate for structural reasons. In these revisions the curved horizontal girders were placed in back of the skin-plate ribs so that the skin plate would not act as part of a main beam, and the timber fenders were extended to within 8 in. of the full radius of the gate for safety reasons. The first gate incorporating these revisions was designed for replacement of the existing gates at Vermilion Lock. One leaf of the model of the improved sector gate was modified to reproduce the Vermilion gate at the nose of the gate leaf. This gate leaf was tested at a scale of 1:20 in the facilities and by the procedures described in the basic report. (Author)

Document Details

Document Type
Technical Report
Publication Date
Dec 01, 1971
Accession Number
AD0734890

Entities

People

  • Noel R. Oswalt
  • Thomas E Murphy

Tags

DTIC Thesaurus Topics

  • Buildings And Structures
  • Hydraulic Models
  • Model Tests
  • Models
  • Test Facilities

Readers

  • Electrical Engineering
  • Facility/Structural Engineering.