Thermal Aging Studies of Encapsulated Motorette Insulation Systems
Abstract
Thermal aging studies were conducted on four epoxy encapsulated insulation systems on motorettes to establish their thermal ratings. Encapsulation of Class A and B INSULATION SYSTEMS RESULTED IN UPGRADING THE class A system from 105 to 138 C and the Class B system from 130 to 150 C. It is recommended that the encapsulated insulation systems studied be rated thermally Class B.
Document Details
- Document Type
- Technical Report
- Publication Date
- Feb 01, 1968
- Accession Number
- AD0744951
Entities
People
- R. J. Flaherty Jr.