Research and Development of a High Temperature Capacitance Strain Gage for Operation at 2000 F
Abstract
The report describes the research and development of a high temperature capacitance strain gage. The investigation consisted of a materials, configuration, and attachemtn study; a cable evaluation; and a manufacturing and evaluation phase. The final configuration was a rhombic strain frame with a capacitor element composed of Inconel plates and mica dielectric insulators. The overgage length was 1/2 inch.
Document Details
- Document Type
- Technical Report
- Publication Date
- Oct 01, 1971
- Accession Number
- AD0745449
Entities
People
- O. L. Gillette
Organizations
- Hughes Aircraft Company