Test Procedures to Determine Phase Relationship of Loop Antenna AT-317/BRR Using Test Set AN/BRM-1.

Abstract

Specific phase relationships are required between the loop antenna AT-317/BRR foreaft (F/A) and athwart (ATH) loop outputs for a given LORAN C transmitting station bearing. This test procedure was primarily developed to identify these phase relationships at the antenna input to the AN/WPN-3 navigation equipment. Additional tests have been included in these test procedures to supplement antenna system maintenance techniques. (Author)

Document Details

Document Type
Technical Report
Publication Date
Nov 01, 1969
Accession Number
AD0750739

Entities

Organizations

  • Navy Underwater Sound Laboratory

Tags

DTIC Thesaurus Topics

  • Antennas
  • Loop Antennas
  • Maintenance
  • Navigation
  • Test Sets
  • Transmitting