Some Properties of an Injection-Locked Pulsed Magnetron

Abstract

The paper describes injection-locking of positive-pulse microwave magnetrons by a stabilized low power source. A coherent echo-detection system using an acoustic delay medium to simulate radar pulse return is employed to study phase coherence of injection-locked positive-pulsed magnetrons. Pulse-to- pulse coherence at approximately 9 GHz is observed for extremely low input powers: the maximum output to input ratio-for which such locking is observed-is about 10,000. (Author Modified Abstract)

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Jan 16, 1973
Accession Number
AD0758198

Entities

People

  • Peter A. Devito

Organizations

  • Air Force Cambridge Research Laboratories

Tags

Communities of Interest

  • Energy and Power Technologies

DTIC Thesaurus Topics

  • Air Force
  • Analyzers
  • Bandwidth
  • Coherent Radar
  • Detection
  • Detectors
  • Doppler Radar
  • Frequency
  • Frequency Modulation
  • Microwave Oscillators
  • Oscillators
  • Phase Shift
  • Physics Laboratories
  • Radar
  • Spectra
  • Spectrum Analyzers
  • X Band

Fields of Study

  • Physics

Readers

  • Electronics Engineering
  • Radar Systems Engineering.