10.6-Micrometer Detector Array

Abstract

An initial design for a 10 x 10 element heterodyne array was developed using 77 K, 1500-MHz photodiodes. Five PV-HgCdTe 150-MHz MHz photodiodes were then tested on a subassembly of a heterodyne matrix array structure with NEP's below 1.5 x 10 to the minus 19th power W/Hz measured out to 150 MHz. A thermal analysis was performed for 77 and 4.2 K matrix arrays with 150 and 1500 MHz operation to determine the cooler requirement for each case and the effect of the thermal loading on photomixer performance. A thermal mockup of the 77 K, 1500-MHz, 10 x 10 array was tested verifying the multi-cable thermal load analysis, the greater than 30-dB isolation between channels, and the greater than 24-hour operating time of the thermal mockup dewar.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Feb 01, 1973
Accession Number
AD0758714

Entities

People

  • A. Dinardo
  • D. Yustein
  • J. Wolczok
  • R. Augeri
  • R. Lange

Organizations

  • Eaton Corporation

Tags

Communities of Interest

  • Air Platforms
  • Energy and Power Technologies

DTIC Thesaurus Topics

  • Batch Processing
  • Coaxial Cables
  • Detectors
  • Equations
  • Fabrication
  • Focal Planes
  • Frequency
  • Frequency Response
  • Heat Sinks
  • Image Dissection
  • Local Oscillators
  • Materials
  • Measurement
  • Plane Waves
  • Quantum Efficiency
  • Thermal Resistance
  • Two Dimensional

Readers

  • Electronics Engineering
  • Software Engineering
  • Thermal Physics or Thermal Science.

Technology Areas

  • Directed Energy