KIVA-I MHD Generator Modifications and Tests.

Abstract

The AFAPL-MHD Facility (KIVA-I) was used to conduct an extensive series of tests on the pegwall diagonally connected generator. Extensive knowledge was gained in the areas of conductivity, oxygen-to-fuel ratios, interelectrode connection angles, seed particle geometry, and optimum loading conditions. A peak power of 210 KW was achieved. A DC-to-DC Inverter was successfully operated on the MHD generator, providing an output of 50 KW at 50 KV dc. Numerous modifications were made to the KIVA-I facility, including a new high-speed data acquisition system, a close circuit television system, a pulse-control network for the main burner, a new set of pole faces for the magnet, a digital display panel, and an instrumented copper electrode assembly. (Author)

Document Details

Document Type
Technical Report
Publication Date
Aug 01, 1973
Accession Number
AD0770063

Entities

People

  • Lester W. Buechler
  • Robert A. Nimmo

Tags

Communities of Interest

  • Energy and Power Technologies

DTIC Thesaurus Topics

  • Acquisition
  • Assembly
  • Conductivity
  • Data Acquisition
  • Electrodes
  • Generators
  • Geometry
  • Inverters
  • Particles
  • Peak Power
  • Power
  • Television Systems

Fields of Study

  • Physics

Readers

  • Aerospace Test and Evaluation
  • Combustion and Flow Dynamics.
  • Electrical Engineering