Composite Shear Strength - Tube Torsion vs Short Beam Shear
Abstract
Experimental evidence is presented for transversely isotropic glass- epoxy to show that shear strength determinations using the short-beam shear method (ASTM D2344-67) AGREE WELL WITH THE RESULTS OF TUBE TORSION FOR A CERTAIN VOLUME FRACTION RANGE. In all cases short-beam shear results bound tube torsion results from below. Comparison of short beam and tube torsion shear strength may be a convenient measure of fabrication effectiveness.
Document Details
- Document Type
- Technical Report
- Publication Date
- Oct 01, 1973
- Accession Number
- AD0770596
Entities
People
- M. J. Michno Jr.
- R. E. Lavengood
Organizations
- Monsanto