3 KW Closed Rankine-Cycle Powerplant with a Turbine Expander.

Abstract

The report describes the design of a 3 kw generator set driven by an organic Rankine cycle engine. Power is produced with a turbine-gearbox expander arrangement. The turbine speed of 70,200 rpm is geared down internally to the sealed system to 3,600 rpm so that a low speed shaft seal of proven performance can be used to transmit the turbine output to a standard military generator. The system is completely self-contained with controls designed to maintain working fluid cycle conditions and turbine speed constant and independent of load. The system uses an organic working fluid (Fluorinol-85) rather than water to avoid problems associated with freezing and high temperature lubrication. At full load the cycle operates with turbine inlet conditions of 530F and 480 psia and a condensing pressure of 29 psia (202F). (Author)