The Effects of Chromate Conversion Coating Aluminum Stress Corrosion Specimens.

Abstract

A major problem in assessing stress corrosion susceptibility of 7XXX series aluminum alloys by alternate immersion in a 3.5% NaCl aqueous solution is excessive pitting corrosion. An investigation was initiated to determine if chromate conversion surface treatment would improve the sensitivity of the alternate immersion test by minimizing pitting and gross corrosion. Results of alternate immersion tests of coated and bare 7075 tensile bar and C-ring specimens showed that stress corrosion cracks were easier to detect on chromate conversion coated specimens. (Author)

Document Details

Document Type
Technical Report
Publication Date
Mar 18, 1974
Accession Number
AD0777031

Entities

People

  • I. S. Shaffer

Organizations

  • Naval Air Warfare Center Warminster

Tags

DTIC Thesaurus Topics

  • Alloys
  • Aluminum
  • Aluminum Alloys
  • Aqueous Solutions
  • Chromium Compounds
  • Conversion
  • Corrosion
  • Sensitivity
  • Stress Corrosion
  • Surface Finishing

Fields of Study

  • Materials science

Readers

  • Materials Science and Engineering.
  • Surface Coatings Technology.
  • Systems Analysis and Design